Technical parameters:
Supply Voltage |
AC380V ±10% 50HZ ±1% (three-phase five-wire system) | sample size (statistics) | 4 |
Maximum power consumption | 51.5KW | Setting Pulse Rate |
0-2Hz Acquisition speed 500Hz |
Overall dimensions |
(1) Test bench 2000 (length) × 1200 (thickness) × 2000 (height) (2) Hydraulic pump station 2000 (L) × 1200 (Thick) × 2200 (H) (3) Electrical control box 900 (L) × 650 (Thick) × 2000 (H)
(4) Cooling unit 2500 (L) x 1200 (Thick) 1000 (H) |
Specimen length |
1) The nominal inner diameter of the hose in 22mm (including 22mm) or less according to the formula (2) 180 ° bending, free length = π (r + d / 2) + 2d ............... (2) The nominal inner diameter of the hose more than 22mm calculated according to formula (3) 90 ° bending, free length = π / 2 (r + d / 2) + 2d .................. (3) where: r -Minimum bending radius; d - hose outer diameter |
Weight |
1.86T | Maximum pressure | 100MPa |
Test Fluid | According to GB/T3141-1994, the test liquid should meet the requirements of N46 at 40℃. | Maximum number of pulses |
999,999 times. |
Test temperature setting range |
50-150℃ Temperature control accuracy ±3 degrees |
|