Technical parameters:
metal cover |
1200mm high, 300mm wide, 450mm deep, open front, closed top and bottom |
Combustion box volume |
1 m3 (external dimensions 2150*1200*550mm) |
fuels |
Gas. Methane (customer supplied) |
Power consumption of the whole machine |
0.6KW |
Nominal power 1kw torches |
|
Integrated Burning Lamp Calibration Unit |
|
The machine will automatically stop ignition when the set combustion time reaches the preset time. |
|
Ignition is automatic high-voltage electric |
|
One air mass flow meter, one gas mass flow meter each |
|
Touch screen operation with PLC control of air and gas flow rate |
|
Calibration temperature controller, calibration time, test time digital display table display |