DLRF-3000 Mining cable load burning test

Overview:

DLRF-3000 mining cable load combustion test according to MT818 and MT 386 coal mine flame retardant cable flame retardant test methods and determination rules developed and produced, automated programmed control, touch-screen operation, the experimental results can be selectively saved, ignition perception control safety features. Shell made of high-quality 304 stainless steel, easy to operate, high degree of integration of the machine; is the first choice for quality inspection departments at all levels, cable production enterprises, universities and colleges and other laboratories.

Technical parameters:

Input Voltage

AC 380V 50HZ
Combustion box size

1100×525×900mm (L*W*H)

Power of the whole machine

24KW
Automatic adjustment of load current after setting

0-3000A

Height-adjustable torch, torch angle

90°
Temperature range

K-type thermocouple 0~800℃

Integrated Burning Lamp Calibration Unit

Integrated Burning Lamp Calibration Unit
Temperature control meter display range

0 to 1999.9°C

Timer range

0~999.99S/M/H
Test volume

0.5m3.look afterexhaust system

Adjustable Cable Bracket

Fully automatic program touch screen control, all the tests are done with one key.