Technical parameters:
operating voltage |
AC 220V±10% 50Hz |
electric power consumption |
2.3KW |
constant temperature |
(20±5)℃. Inlet and outlet air flow (5000±500)L/min, adjustable |
air flow |
0-30m3/min adjustable |
air supply |
Propane(0.1Mpa), Air(0.1Mpa), Gas source provided by customer |
Timing range |
0-60min can be set |
Anemometer Measuring Range |
0-30m/s |
Measurement accuracy |
±0.2m/s |
Test chamber size |
Length 2184mm, Width 1156mm, Height 5213mm |
Dimensions of standard steel ladder for testing (vertical) |
500(W)×3,500(H) |
Wide steel ladder dimensions (vertical) |
800(W) x 3,500(H) |
Burning surface size |
(L)257×(W)4.5 mm |
Main components |
Combustion box (with ash hopper and drainage tank), 2 combustion ladders (800mm, 500mm each), 2 341mm blowtorches (with venturi mixer), 1 fixed blowtorch traveling trolley, electric combustion ladder lifting and lowering system, 1 frequency control inlet axial blower, 1 set of air volume measurement system, 2 water sprinkler pipelines, 2 nitrogen fire extinguishing pipelines, and 1 operation desk. |
spray tower |
1 unit |
Smoke exhaust fan |
1 unit |
2 sets of burning lamp heads |
|
Intelligent control, electronic ignition, automatic timing |
|
PLC control of the burner, touch screen operation |