Technical parameters:
Heating temperature |
Room temperature~180℃ |
Control temperature accuracy |
±1°C |
Pressure setting and detection range |
0~25MPa 0~100KPa |
Pressure control accuracy |
≥1MPa ±0.5% ≤100 KPa ±0.1% |
maximum time |
0.0~9999h59min59s |
timing accuracy |
±0.1s |
Test Setting Frequency |
0.1000~0.5000HZ (settable) |
Control frequency accuracy |
±0.1% |
Count range |
0~4×105 times (settable) |
counting accuracy |
± 1 time |
Cooling temperature range |
Room temperature ~ -45°C (inverter refrigeration control) |
control accuracy |
±2°C |
Drive travel range |
0.00~20.00mm (settable) |
Displacement detection accuracy |
±0.01mm |
Volume measurement range |
0.0ml~500 ml |
Measurement accuracy |
±0.5 ml |
Residual pressure test range |
0.0~1Mpa |
Measurement accuracy |
±0.01 Mpa |
Load power setting range |
0 to 150W |
Load power control accuracy |
±0.1W |
Force detection range |
0.00~2500N |
Detection accuracy |
±0.3 per cent |